HANNA Ammonia High Range Handheld Colorimeter

£79.95

1 in stock

Description

The HI-733 Checker is a simple, accurate, and cost effective way to measure high ranges of ammonia in fresh water.

Designed as a more accurate alternative to chemical test kits, the HI-733 provides quick, accurate results in four easy steps.

The HI-733 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

 

Ideal for:

  • Water Quality
  • Education
  • Wastewater
  • Freshwater Aquariums
  • Environmental

 



Features

  • Palm-sized design
  • ±1.0ppm ±5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

 

Four steps. One click. Instant Readout.

1. ‘Zero’ the Checker®HC with your vial inside




2. Place a 10ml water sample into the vial and add your reagent




3. Place your vial into your Checker®HC




4. Press the button and read the results

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Use reagents HI-733-25 with the HI-733 Ammonia High Range Colorimeter Checker®HC, x 25 tests.

Use Calibration Check Set HI-733-11 with the HI-733 Ammonia High Range Colorimeter Checker®HC.

Specifications

Specifications list

Specifications

Range 0.0 to 99.9 ppm as NH4+
Resolution 0.1 ppm
Accuracy (@20°C/68°F) ±1.0ppm ±5% of reading
Measurement Method Colorimetric
Light Source LED @470 nm
Light Detector Silicon photocell
Method Adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Power Supply Battery – 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
Ordering information: Supplied with sample cuvettes with caps (2), Ammonia HR reagent starter kit (reagents for 10 tests), syringe with tip, plastic pipette, battery, instructions and quick start guide.
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
 Interference may be caused by: Acetone
Alcohols
Aldehydes
Glycine
Hardness above 1 g/L
Iron
Organic chloramines
Sulphide
Various aliphatic and aromatic amines

Reviews

There are no reviews yet.

Be the first to review “HANNA Ammonia High Range Handheld Colorimeter”

Your email address will not be published. Required fields are marked *