HANNA Ammonia Medium Range Handheld Colorimeter
The HI-715 Checker is a simple, accurate, and cost effective way to measure medium ranges of ammonia in fresh water.
Designed as a more accurate alternative to chemical test kits, the HI-715 provides quick, accurate results in four easy steps.
The HI-715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Features:
- Small palm-sized design
- Accurate from ±0.05ppm ±5% of reading
- Dedicated to a single parameter
- Uses a single AAA battery
- Auto Power Off after 10 minutes in inactivity
- Built-in timer for timed reaction readings
Ideal for:
- Ponds
- Water Quality
- Education
- Aquariums
- Environmental
Order Information:
The HI-715 Checker is supplied with 2 cuvettes and caps, Ammonia MR reagents x 25 tests (HI-715-25), 1 x 1.5V AAA battery, and an instruction manual.
Not included: Calibration set HI-715-11.
Four steps. One click. Instant Readout.
1. ‘Zero’ the Checker®HC with your vial & 10ml water sample inside
2. Take your vial out and add your reagent
3. Place your vial into your Checker®HC
4. Press the button and read the results
Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
Use Reagents HI-715-25 with the HI-715 Ammonia Medium Range Handheld Colorimeter - Checker®HC, x 25 tests.
Use Calibration Check Set HI-715-11 with the Hi-715 Ammonia Medium Range Colorimeter - Checker®HC.
Specifications
Specifications list
Specifications
Range | 0.00 to 9.99 ppm NH3-N | |
Resolution | 0.01 | |
Accuracy @ 25°C | ±0.05 ppm ±5% of reading | |
Light source | LED @ 470 nm | |
Light Detector | Silicon photocell | |
Method | Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. | |
Environment | 0 to 50°C; RH max 95% non-condensing | |
Battery Type | (1) 1.5V AAA | |
Auto-off | After ten minutes of non-use | |
Dimensions | 81.5mm x 61mm x 37.5mm | |
Weight | 64g | |
Ordering Information | HI-715 Checker® is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests, battery, instructions and quick start guide. |
PLEASE NOTE: | In some cases, samples may contain other parameters which may interfere with results | |
Interference may be caused by: | Acetone Alcohols Aldehydes Glycine Hardness above 1 g/L Iron Organic chloramines Sulphide Various aliphatic and aromatic amines |