Skip to content
Join Elite Koi's Live Koi Auction every Saturday from 10am
Join Elite Koi's Live Koi Auction every Saturday from 10am

HANNA Ammonia Medium Range Handheld Colorimeter

Sold out
£79.95

The HI-715 Checker is a simple, accurate, and cost effective way to measure medium ranges of ammonia in fresh water.

Designed as a more accurate alternative to chemical test kits, the HI-715 provides quick, accurate results in four easy steps.

The HI-715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

 


Features:

  • Small palm-sized design
  • Accurate from ±0.05ppm ±5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Ideal for:

  • Ponds
  • Water Quality
  • Education
  • Aquariums
  • Environmental

 


Order Information:

The HI-715 Checker is supplied with 2 cuvettes and caps, Ammonia MR reagents x 25 tests (HI-715-25), 1 x 1.5V AAA battery, and an instruction manual.

Not included: Calibration set HI-715-11.

Four steps. One click. Instant Readout.

1. ‘Zero’ the Checker®HC with your vial & 10ml water sample inside




2. Take your vial out and add your reagent




3. Place your vial into your Checker®HC




4. Press the button and read the results



Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.



Use Reagents HI-715-25 with the HI-715 Ammonia Medium Range Handheld Colorimeter - Checker®HC, x 25 tests.



Use Calibration Check Set HI-715-11 with the Hi-715 Ammonia Medium Range Colorimeter - Checker®HC.

Specifications

Specifications list

Specifications

Range 0.00 to 9.99 ppm NH3-N
Resolution 0.01
Accuracy @ 25°C ±0.05 ppm ±5% of reading
Light source LED @ 470 nm
Light Detector Silicon photocell
Method Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Environment 0 to 50°C; RH max 95% non-condensing
Battery Type (1) 1.5V AAA
Auto-off After ten minutes of non-use
Dimensions 81.5mm x 61mm x 37.5mm
Weight 64g
Ordering Information HI-715 Checker® is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests, battery, instructions and quick start guide.
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
 Interference may be caused by: Acetone
Alcohols
Aldehydes
Glycine
Hardness above 1 g/L
Iron
Organic chloramines
Sulphide
Various aliphatic and aromatic amines